CSA ANSI NGV 5.2:23

  • standard by CSA Group, 01/27/2023
  • Vehicle fueling appliances (VFA)
  • Category: CSA GROUP

$350.00 $175.00

Full Description

Preface 

This is the second edition of CSA/ANSI NGV 5.2, Vehicle fuelling appliances (VFA) . It supersedes the previous edition published in 2017. The following are major changes to this edition: a) addition of coverage for ANG appliances, incorporating coverage from CSA IR-7-16; b) addition of Table 8 to address constituent limits and additional natural gas properties; c) addition of test gas requirements under Clause 8.2.1 for testing to apply the physical characteristics of CSA Group standards "Test Gas A" used in performance testing under other CSA Group standards with specific reference to Test Gas A heating value and specific gravity (shown in Table 5 and taken from CSA/ASNI Z21.47/CSA 2.3); d) removal of the test method for verifying material adhesion and legibility; e) harmonization coverage to the extent possible with CSA/ANSI NGV 5.1; and f) added language for accessibility. The first edition of CSA NGV 5.2 was developed using the requirements in CSA 12.6, Vehicle refuelling appliances; CSA/ANSI NGV 5.1, Residential fuelling appliances; and current code requirements. The CSA NGV 5.2/12.6 Technical Subcommittee reviewed coverage in CSA 12.6 and CSA/ANSI NGV 5.1 to create a new Standard that would resolve overlapping conflicting requirements and focus on coverage for vehicle fuelling appliances for other than residential applications. The document was designated CSA/ANSI NGV 5.2 to remove potential confusion in the field with equipment marked as complying with CSA 12.6. CSA Group acknowledges that the development of this Standard was made possible, in part, by the financial support of Natural Resources Canada. For general information on the Standards of the Canadian Electrical Code, Part II, see the Preface of CAN/CSA-C22.2 No. 0, General Requirements — Canadian Electrical Code, Part II. This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was prepared by the Subcommittee on Compressed Natural Gas Vehicle (NGV) Fuelling Appliances, under the jurisdiction of the Natural Gas Transportation Technical Committee, and has been formally approved by the Technical Committee, American National Standards Institute, and the Interprovincial/Territorial Gas Advisory Council. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. 

Scope 

1.1 General This Standard details mechanical, physical, and electrical requirements for a newly manufactured appliance that compresses natural gas for vehicles and dispenses directly into a) the vehicle natural gas fuel storage system, referred to as a vehicle fuelling appliance (VFA); or b) the vehicle’s activated carbon adsorbents-based adsorbed natural gas (ANG) fuel storage system, referred to as a vehicle fuelling appliance (VFA). This Standard applies to appliances that incorporate compression and dispensing in the same appliance. Notes: 1) Residential fuelling appliances (RFA) are addressed in CSA/ANSI NGV 5.1. 2) Devices dedicated only to dispensing fuel into vehicles are addressed in CSA/ANSI NGV 4.1. 

1.2 Application This Standard applies to all appliances that are a) intended for natural gas only (see Clause 1.1); b) intended for outdoor or indoor installation; c) intended for ambient temperatures not below −40 °C (−40 °F); d) intended for nominal voltage not exceeding 480 V AC; e) certified as a system with temperature compensated pressure limits for delivery of fuel for i) direct fuelling of vehicles; ii) fuelling of vehicles from the system’s internal storage; iii) filling of external natural gas storage systems; or iv) any combination of the above; f) equipped with maximum inlet flow rate not exceeding 10 SCFM (17 SCMH); g) for installation in non-residential occupancies; h) intended to meet installation fire safety requirements in accordance with the requirements of the applicable Code; i) for connection to a single vehicle, multiple vehicles, or storage systems; j) intended for installation in non-hazardous locations; k) for connection to a single or multiple vehicle storage system or external storage systems, with no single storage system having a total capacity of less than 80 L water volume; and l) intended for installation in accordance with NFPA 52 or CSA B108.1 where not in conflict with the requirements in this document. These requirements apply only to ANG appliances for use with vehicle or external fuel storage systems that contain activated carbon-adsorbent material with an MDP/RCP ratio less than or equal to 1.5, and that have a service pressure of 6205 kPa (900 psig). 

1.3 Pressure references All references to "kPa" and "psig" throughout this Standard are to be considered gauge pressures unless otherwise specified. 

Product Details

Edition:
2nd
Published:
01/27/2023
ISBN(s):
9781488344459
Number of Pages:
105
File Size:
1 file , 1.3 MB
Product Code(s):
2430198, 2430198
Note:
This product is unavailable in Russia, Ukraine, Belarus

Document History

CSA ANSI NGV 5.2:23

CSA ANSI NGV 5.2-2017 (R2021)

CSA C22.2 NO. 198.2-15

CSA C22.2 NO. 198.2-15

Sealed Wire Connector Systems..

$152.00 $303.00

CSA C22.3 NO. 1-15 (R2020)

CSA C22.3 NO. 1-15 (R2020)

Overhead Systems, Includes Errata (2016) and Update No. 1 (2018)..

$163.00 $325.00

CSA C22.2 NO. 207-15 (R2020)

CSA C22.2 NO. 207-15 (R2020)

Portable and Stationary Electric Signs and Displays..

$48.00 $95.00

CSA C22.2 No. 113-15

CSA C22.2 No. 113-15

Fans and Ventilators..

$165.00 $330.00