CSA N285.0-12/N285.6 SERIES-12

  • standard by CSA Group, 08/01/2012
  • General requirements for pressure-retaining systems and components in CANDU nuclear power plants/Material Standards for reactor components for CANDU n
  • Category: CSA GROUP

$20.00 $10.00

Full Description

Preface

This is the second edition of CSA N285.0/N285.6 Series, General requirements for pressure-retaining systems and components in CANDU nuclear power plants/Material Standards for reactor components for CANDU nuclear power plants. It supersedes the previous edition of the CSA N285.0/N285.6 Series published in 2008, the previous editions of CSA N285.0 published in 2006, 1995, 1991, and 1981, and the previous editions of the CSA N285.6 Series published in 2005 and 1988.------------------------------------------------------------------------ N285.0-12 - General requirements for pressure-retaining systems and components in CANDU nuclear power plants

Scope

1.1 This Standard specifies the technical requirements for the design, procurement, fabrication, installation, modification, repair, replacement, testing, examination, and inspection of, and other work related to, pressure-retaining systems, components, and supports over the service life of a CANDU nuclear power plant. 1.2 This Standard applies to all pressure-retaining systems, including their components and supports, in a CANDU nuclear power plant. 1.3 This Standard applies to containment components, but does not apply to concrete containment structures. 1.4 This Standard does not apply to portable assemblies of pressurized items that are temporarily connected to a system or component to enable testing, venting, draining, calibration, or other maintenance activities, provided that they (a) do not reduce the ability of a system to perform its design safety function; (b) are under surveillance when connected and are removed upon completion of their function; and (c) are constructed to Standards deemed by the licensee to be suitable for the application. Note: Safety analysis, environmental qualification programs, or seismic qualification may be used to satisfy the conditions in this Clause. 1.5 In this Standard, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the standard.    Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material.    Notes to tables and figures are considered part of the table or figure and may be written as requirements.    Annexes are designated normative (mandatory) or informative (nonmandatory) to define their application. 1.6 The values given in SI units are the units of record for the purposes of this Standard. The values given in parentheses are for information and comparison only. ---------------------------------------------------------------------------- N285.6.1-12 - Pressure tubes for use in CANDU fuel channels

1 Scope

This Standard specifies requirements for the fabrication and properties of seamless zirconium-2.5wt % niobium (Zr-2.5Nb) alloy pressure tubes for use in fuel channels in CANDU reactors.------------------------------------------------------------------------------- N285.6.2-12 - Seamless zirconium alloy tubing for reactivity control units

Scope

This Standard specifies requirements for the fabrication and properties of seamless zirconium alloy tubing, Grades R60802 and R60804, with diameter to wall thickness ratios less than 80. This tubing is used for reactivity control units in CANDU reactors.------------------------------------------------------------------------------- N285.6.3-12 - Annealed seamless zirconium alloy tubing for liquid injection shutdown system (LISS) nozzles

Scope

This Standard specifies requirements for the fabrication and properties of seamless zirconium-tin alloy tubing, Grade R60802 or R60804, which is suitable for use in liquid injection shutdown system (LISS) nozzles located in the moderator water in the core of a CANDU reactor.------------------------------------------------------------------------------- N285.6.4-12 - Thin-walled, large-diameter zirconium alloy tubing

Scope

This Standard specifies requirements for the fabrication and properties of thin-walled, large-diameter tubing made from zirconium-tin alloys, Grade R60802 or R60804. Notes: (1) Thin-walled, large diameter tubing has a diameter to wall thickness ratio greater than 50. (2) This tubing can be used as calandria tubes and as tubes for reactivity control units in a CANDU reactor, and may be processed in the seamless or seam-welded condition.-----------------------------------------------------

Product Details

Edition:
2nd
Published:
08/01/2012
ISBN(s):
9781771390194
Number of Pages:
240
File Size:
1 file , 6.3 MB
Product Code(s):
2422019, 2422801, 2422019
Note:
This product is unavailable in Russia, Ukraine, Belarus

Document History

CSA N285.0:23/CSA N285.6 SERIES:23

CSA N285.0-17/N285.6 SERIES-17 (R2022)

CSA N285.0-12/N285.6 SERIES-12

CSA N285.0-08 / N285.6 SERIES-08

CSA N285.6 SERIES-05

CSA T568.1-1-05 (R2010)

CSA T568.1-1-05 (R2010)

Commercial Building Telecommunications Cabling Standard - Part 1: General Requirements - Addendum 1 ..

$94.00 $188.00

CSA T568.1-2-05 (R2010)

CSA T568.1-2-05 (R2010)

Commercial Building Telecommunications Cabling Standard - Part 1: General Requirements - Addendum 2 ..

$91.00 $182.00

CSA T568.1-4-05 (R2010)

CSA T568.1-4-05 (R2010)

Commercial Building Telecommunications Cabling Standard - Part 1: General Requirements - Addendum 4 ..

$103.00 $205.00

CSA T568.2-05 (R2010)

CSA T568.2-05 (R2010)

Commercial Building Telecommunications Cabling Standard - Part 2: Balanced Twisted-Pair Cabling Comp..

$96.00 $192.00