IEEE 484-2019

  • standard by IEEE, 07/17/2020
  • IEEE Recommended Practice for Installation Design and Installation of Vented Lead-Acid Batteries for Stationary Applications
  • Category: IEEE

$56.00 $28.00

Full Description

Scope

This recommended practice provides recommended design practices and procedures for storage, location, mounting, ventilation, instrumentation, preassembly, assembly, and charging of vented lead-acid batteries. Required safety practices are also included. This recommended practice is applicable to full-float stationary applications where a battery charger normally maintains the battery fully charged and supplies the direct current (dc) loads. However, specific applications, such as emergency lighting units, semiportable equipment, and alternate energy applications, may have other appropriate practices that are beyond the scope of this recommended practice. The portions of this recommended practice that specifically relate to personnel safety are mandatory instructions and are designated by the word shall; however, all other portions are recommended practices and are designated by the word should. Sizing, maintenance, capacity testing, charging equipment, dry-charged units, and consideration of other types of batteries are beyond the scope of this recommended practice.

Purpose

This recommended practice provides a general format for the preparation of test procedures and suggests the points to be considered by technical committees in the preparation of specific instructions for the thermal evaluation of insulation systems for electrical equipment. The thermal evaluation of an insulation system involves the following thermal factors of influence: a) Exposure temperature b) Ambient temperature c) Temperature gradient d) Rate of temperature change

Abstract

Revision Standard - Active. Recommended design practices and procedures for storage, location, mounting, ventilation, instrumentation, preassembly, assembly, and charging of vented lead-acid batteries are provided. Required safety practices are also included. These recommended practices are applicable to all stationary applications. Specific applications, such as emergency lighting units, semiportable equipment, and alternate energy applications, may have other appropriate practices and are beyond the scope of this recommended practice.

Product Details

Published:
07/17/2020
ISBN(s):
9781504463324, 9781504463317, 9781504468510, 9781504469548
Number of Pages:
27
File Size:
1 file , 1.6 MB
Redline File Size:
2 files , 8.8 MB
Product Code(s):
STDRL23991, STD23991, STDPD23991, STDPL23991
Note:
This product is unavailable in Russia, Ukraine, Belarus

Document History

IEEE 484-2019

IEEE 484-1981

IEEE 484-1987

IEEE 484-2002

IEEE 484-1996

IEEE 944-1986

IEEE 944-1986

IEEE Recommended Practice for the Application and Testing of Uninterruptible Power Supplies for Powe..

$67.00 $134.00

IEEE 991-1986

IEEE 991-1986

IEEE Standard for Logic Circuit Diagrams..

$45.00 $90.00

IEEE 535-1986

IEEE 535-1986

IEEE Standard for Qualification of Class 1E Lead Storage Batteries for Nuclear Power Generating Stat..

$54.00 $107.00

IEEE 180-1986

IEEE 180-1986

IEEE Standard Definitions of Primary Ferroelectric Terms..

$31.00 $62.00